Compass Display (For Fx Cruiser High Output); Air Temperature Display (For Fx Cruiser High Output) - Yamaha WaveRunner Service Manual

Hide thumbs Also See for WaveRunner:
Table of Contents

Advertisement

+
ELEC
INDICATION SYSTEM
N
Compass display
(for FX Cruiser High Output)
1. Check:
• Compass display
Incorrect reading → Replace the com-
pass sensor.
Checking steps:
• Using a compass for reference, point the
watercraft north.
• Turn on the multifunction meter and
check that "NORTH" appears on the
meter.
• If "NORTH" does not appear on the multi-
function meter, replace the compass sen-
sor.
NOTE:
Be sure to check the compass display again
after replacing the compass sensor. If the
compass display is still incorrect, replace
the multifunction meter.
Air temperature display
(for FX Cruiser High Output)
1. Check:
• Air temperature display
Incorrect reading → Replace the com-
pass sensor.
Checking steps:
• Measure the ambient air temperature.
• Turn on the multifunction meter and
check the air temperature displayed on
the meter.
• If the air temperature displayed on the
multifunction meter is more than ± 5 °C
(9 °F) different from the ambient air tem-
perature, replace the compass sensor.
NOTE:
Be sure to check the air temperature dis-
play again after replacing the compass sen-
sor. If the air temperature display is still
incorrect, replace the multifunction meter.