Siemens RUGGEDCOM RS910L Installation Manual page 24

Hide thumbs Also See for RUGGEDCOM RS910L:
Table of Contents

Advertisement

Chapter 2
Installing the Device
IMPORTANT!
The serial console port is intended to be used only as a temporary connection during initial
configuration or troubleshooting, and should only be used in a safe area (as defined by IEC 60079-0,
Edition 6.0).
Use the following settings to connect to either port:
Speed
Data Bits
Stop Bit
Parity
Flow Control
Terminal ID
Speed
The serial console port implements RS232 DCE (Data Communication Equipment) on a DB9 connector. The
following is the pin-out for the port:
Figure 8: Serial DB9 Console Port
a
Connected internally.
b
Connected internally.
Communication Ports
Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM
ROS console and Web interfaces via the device's IP address. The factory default IP address for the RUGGEDCOM
RS910L is https://192.168.0.1.
For more information about available ports, refer to
14
57600 Mbps
8
1
None
Off
VT100
57600 Mbps
5
1
9
6
Pin
a
1
2
3
a
4
5
a
6
b
7
b
8
9
Chapter 3, Communication
RUGGEDCOM RS910L
Installation Guide
Name
Description
Reserved (Do Not Connect)
TX
Transmit Data
RX
Receive Data
Reserved (Do Not Connect)
GND
Signal Ground
Reserved (Do Not Connect)
Reserved (Do Not Connect)
Reserved (Do Not Connect)
Reserved (Do Not Connect)
Ports.
Connecting to the Device