Wall Mounting Procedure

• Check the wall mounting kit and the wall to determine their suitability.
• The maximum distance between the Node C and the Interface Unit depends on
the length of the cable bridge by which they will be connected (see table 3-1
Mounting distance). Thus, before marking the mounting positions, check the
length of the cable bridge and make sure to install the units at a suitable distance.
Mounting style:
Length of cable bridge: 500 mm
Maximum distance
* Maximum distance is referring to distance between the cabinet sides
** It is recommended to install the Node C above the
between top of lower and bottom of upper unit
Note:
The following figures show units that are mounted beside each
other. To install one above the other proceed in the same way, also
observing the specified mounting distance from table 3-1.
• Mark the position of the eight drilling holes (four per unit) for the Node C and
Interface Unit according to figure 3-1. Please observe that the figure always
shows a pair of drill holes for each position. Only drill one of each pair.
Page 14
User's Manual for Node C Network Elements
beside each other*
800 mm
140 mm
400 mm
table 3-1 Mounting distance
figure 3-1 Positions of drilling holes
PRELIMINARY
one above the other**
2000 mm
only 2000 mm possible
1600 mm
1000 mm (min.=300 mm)