I I I .
Main Circuit Breaker: The main circuit breaker is a safety feature built into your power chair. When the batteries and the
motors are heavily strained (e.g., from excessive loads), the main circuit breaker trips to prevent damage to the motors and
the electronics. If the circuit trips, allow your power chair to "rest" for approximately one minute. Next, push in the circuit
breaker button, turn on the controller, and continue normal operation. If the main circuit breaker continues to trip repeat-
edly, contact your authorized Pride Provider.
Motor Connectors: This is where the controller connects to the motors. The motor connectors are color-coded with red
and yellow labels. The label color on the motor connector corresponds with the label color on the power pod.
Battery Connector: This is where the controller connects to the batteries.
Power Seat Connector: This is where the power seat actuator is connected to the power pod.
Charger Inhibit Connector: The charger inhibit enables the onboard charger to disable the controller during charging.
See VII. "Operation."
CHARGER INHIBIT
CONNECTOR
MOTOR CONNECTOR
POWER POD
CHARGER POWER
CORD RECEPTACLE
AMMETER
ONBOARD BATTERY CHARGER
Figure 7. Jazzy 1103 Ultra Electrical Components