5-5. INDOOR FAN CONTROL
1. Fan speed
( Table 5 : Indoor Fan Speed )
AU*A12LALN
Operation mode
Cooling
Heating
Dry
Monitoring
AU*A18LALN
Operation mode
Cooling
Heating
Dry
Monitoring
AU*A36LATN
Operation mode
Cooling
Heating
Dry
Monitoring
2. FAN OPERATION
The airflow can be switched in 5 steps such as AUTO, QU, LOW, MED, HIGH, while the indoor
fan only runs.
When [AUTO] is selected, the indoor fan motor runs continuously [MED] mode.
Air flow mode
Speed (rpm)
Hi
650
Me
580
Lo
520
Qu
460
Hi
650
Me+
620
Me
580
520
Lo
Qu
460
Auto
460
S-Lo
300
Air flow mode
Speed (rpm)
Hi
730
Me
630
Lo
540
Qu
460
Hi
830
Me+
770
Me
730
Lo
630
Qu
500
Auto
460
S-Lo
300
Air flow mode
Speed (rpm)
Hi
680
Me
570
Lo
480
Qu
400
Hi / Me+
680
Me
570
Lo
480
Qu
420
Auto
420
S-Lo
300
AU*A14LALN
Operation mode
Cooling
Heating
Dry
Monitoring
AU*A24LALN
Operation mode
Cooling
Heating
Dry
Monitoring
AU*A45LATN
Operation mode
Cooling
Heating
Dry
Monitoring
05-05
Air flow mode
Speed (rpm)
Hi
730
Me
630
Lo
540
Qu
460
Hi
830
Me+
770
Me
730
Lo
630
500
Qu
Auto
460
S-Lo
300
Air flow mode
Speed (rpm)
Hi
960
Me
850
Lo
650
Qu
500
Hi
960
Me+
930
Me
880
Lo
740
Qu
580
Auto
500
S-Lo
300
Air flow mode
Speed (rpm)
Hi
720
Me
590
Lo
500
440
Qu
Hi / Me+
720
Me
590
Lo
500
Qu
440
Auto
440
S-Lo
300

Hide quick links: