Download Print this page

Advertisement

Quick Links

O
M
OPERATING MANUAL
PERATING
ANUAL
BEDIENUNGSANLEITUNG
MODE D'EMPLOI
ROOM AIR CONDITIONER
MANUAL DE FUNCIONAMIENTO
WALL MOUNTED TYPE
MANUALE DI ISTRUZIONI
ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ
MANUAL DE INSTRUÇÕES
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
KULLANIM K‹TABI
KEEP THIS MANUAL FOR FUTURE REFERENCE
DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN
CONSERVEZ CE MODE D'EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT
GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO
CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO
ΚΡΑΤΗΣΤΕ ΤΟ ΕΓΧΕΙΡΙ∆ΙΟ ΓΙΑ ΜΕΛΛΟΝΤΙΚΗ ΑΝΑΦΟΡΑ
GUARDE ESTE MANUAL PARA CONSULTA POSTERIOR
СОХРАНИТЕ НАСТОЯЩЕЕ РУКОВОДСТВО ДЛЯ БУДУЩИХ ССЫЛОК
BU KILAVUZU, DAHA SONRA BAfiVURMAK ÜZERE SAKLAYIN
P/N9377806024

Advertisement

loading

Summary of Contents for Fujitsu AUY18L

  • Page 1 OPERATING MANUAL PERATING ANUAL BEDIENUNGSANLEITUNG MODE D’EMPLOI ROOM AIR CONDITIONER MANUAL DE FUNCIONAMIENTO WALL MOUNTED TYPE MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ MANUAL DE INSTRUÇÕES РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ KULLANIM K‹TABI KEEP THIS MANUAL FOR FUTURE REFERENCE DIESE ANLEITUNG BITTE SORGFÄLTIG AUFBEWAHREN CONSERVEZ CE MODE D’EMPLOI AFIN DE POUVOIR VOUS Y RÉFÉRER ULTÉRIEUREMENT GUARDE ESTE MANUAL PARA PODERLO CONSULTAR EN EL FUTURO CONSERVARE QUESTO MANUALE PER OGNI EVENTUALE FUTURO RIFERIMENTO...
  • Page 2: Table Of Contents

    CONTENTS Fig. 1 SAFETY PRECAUTIONS ........En-1 ADJUSTING THE DIRECTION OF FEATURES AND FUNCTIONS ......En-2 AIR CIRCULATION ..........En-9 NAME OF PARTS ..........En-3 SWING OPERATION ......... En-10 PREPARATION ............ En-4 COIL DRY OPERATION ........En-10 OPERATION ............En-5 MANUAL AUTO OPERATION ......
  • Page 3: Features And Functions

    FEATURES AND FUNCTIONS INVERTER SWING OPERATION At the start of operation, a large power is used to bring the The Air Flow Direction Louvers swings automatically up and room quickly to the desired temperature. Afterwards, the down so that the air speeds to every nook and corner of unit automatically switches to a low power setting for eco- your room.
  • Page 4 NAME OF PARTS Fig. 1 Indoor Unit Fig. 5 Remote Control Unit 1 Operating Control Panel (Fig. 2) L SLEEP button 2 MANUAL AUTO button M MASTER CONTROL button N SET TEMP. button ( When kept on pressing the MANUAL O COIL DRY button AUTO button for more than 10 seconds, the forced cooling operation will start.
  • Page 5: Preparation

    PREPARATION CAUTION! Turn on the Power G Take care to prevent infants from accidentally swallowing batteries. Turn on the circuit breaker. G When not using the Remote Control Unit for an extended period, remove the batteries to avoid possible leakage and Load Batteries (R03/LR03 ×...
  • Page 6 OPERATION To Select Mode Operation Press the START/STOP button (Fig.5 T). The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light. The air conditioner will start operating. Press the MASTER CONTROL button (Fig.5 M) to se- lect the desired mode. Each time the button is pressed, the mode will change in the following order.
  • Page 7 To Stop Operation Press the START/STOP button (Fig. 5 T). The OPERATION Indicator Lamp (red) (Fig. 3 5) will go out. About AUTO CHANGEOVER Operation G When AUTO CHANGEOVER operation first selected, the fan will oper- AUTO: G When AUTO CHANGE OVER opera- ate at very low speed for about one minute, during which time the unit tion is started under the condition of detects the room conditions and selects the proper operating mode.
  • Page 8 TIMER OPERATION Before using the timer function, be sure that the Remote Control Unit is set to the correct current time ( P. 4). To Use the ON timer or OFF timer Press the START/STOP button (Fig. 5 T) To Cancel the Timer (if the unit is already operating, proceed to step 2).
  • Page 9 SLEEP TIMER OPERATION Unlike other timer functions, the SLEEP timer is used to set the length of time until air conditioner operate is stopped. To Use the SLEEP Timer To Cancel the Timer: While the air conditioner is operating or stopped, press the Use the TIMER MODE button to select SLEEP button (Fig.
  • Page 10 ADJUSTING THE DIRECTION OF AIR CIRCULATION Vertical (up-down) direction of airflow is adjusted by pressing the Remote Control Unit’s SET button. Horizontal (right-left) airflow direction is adjusted manually, by moving the Air Flow Direction Louvers. Whenever making horizontal airflow adjustments, start air conditioner operation and be sure that the vertical air direction louvers are stopped.
  • Page 11: Coil Dry Operation

    SWING OPERATION Begin air conditioner operation before performing this procedure. To select SWING Operation Press the SWING button (Fig. 5 V). The SWING Display (Fig. 6 e) will light. In this mode, the Air Flow Direction Louvers will swing automatically to direct the air flow both up and down.
  • Page 12: Cleaning And Care

    CLEANING AND CARE G Before cleaning the air conditioner, be sure to turn it off and disconnect the Power Supply Cord. CAUTION! G Be sure the Intake Grille (Fig. 1 9) is installed securely. G When removing and replacing the air filters, be sure not to touch the heat exchanger, as per- sonal injury may result.
  • Page 13 CLEANING AND CARE Air Cleaning Filter Installation Replacing dirty Air cleaning filters Replace filters with the following components (purchased 1. Open the Intake Grille and remove the Air separately). filters. G POLYPHENOL CATECHIN AIR CLEANING FILTER : UTR-FA03-2 G Negative air ions deodorizing filter: UTR-FA03-3 1.
  • Page 14 TROUBLESHOOTING In the event of a malfunction (burning smell, etc.), immediately stop operation, disconnect the WARNING! Power Supply Plug, and consult authorized service personnel. Merely turning off the unit’s power switch will not completely disconnect the unit from the power source.
  • Page 15: Troubleshooting

    TROUBLESHOOTING Symptom Items to check See Page G Has the circuit breaker been turn off? CHECK ONCE Doesn’t operate at all: MORE G Has there been a power failure? — G Has a fuse blown out, or a circuit breaker been tripped? G Is the timer operating? 7 - 8 G Is the Air Filter dirty?
  • Page 16 OPERATING TIPS Multi-type Air conditioner This indoor unit can be connected to a multi-type outdoor unit. The multi-type air conditioner allows multiple indoor units to be operated in multiple locations. The indoor units may be operated simultaneously, in accordance with their respective output.