Indoor Unit - Fujitsu AU*A12LALN Service Instruction

Cassette type inverter, indoor/outdoor units
Table of Contents

Advertisement

OUTDOOR UNIT
Circuit protection
Fan motor protection
Compressor protection

INDOOR UNIT

Circuit protection
Fan motor protection
Circuit protection
Fan motor protection
Circuit protection
Fan motor protection
Circuit protection
Fan motor protection
Protection form
Current fuse (NEAR THE TERMINAL)
Current fuse
(MAIN PRINTD CIRCUIT BOARD)
Thermal protection program
Thermal protection program (COMPRESSR TEMP.)
Thermal protection program (DISCHARGE TEMP.)
Protection form
Current fuse (PCB)
Thermal protection program
Protection form
Current fuse (PCB)
Thermal protection program
Protection form
Current fuse (PCB)
Thermal protection program
Protection form
Current fuse (PCB)
Thermal protection program
08-11
AOTA18L
+15
OFF:100
-10
+15
ON:95
-10
ON: After 40 minutes
ON: After 7 minutes
Model
AU A12L
AU A14L
3.15A 250V
140±20°C OFF
110±20°C ON
Model
AU A18L
AU A24L
3.15A 250V
140±20°C OFF
110±20°C ON
Model
AU A36L
AU A45L
3.15A 250V
139±15°C OFF
109±19°C ON
Model
AUTA18L
AUTA24L
3.15A 250V
140±20°C OFF
110±20°C ON
Model
AOTA24L
20A 250V
5A 250V
15A 250V
3.15A 250V
+15
°C
OFF:110
°C
-10
+15
°C
ON:105
°C
-10
OFF:110°C
OFF:110°C