Water Module Wiring - Dimplex ECS150HP40A-580 Installation And User Instructions Manual

A class heat pump cylinders up to 250l. ec-eau cylinder range
Table of Contents

Advertisement

5.9 Water Module Wiring

All wiring must be carried out by a suitably
qualified person and must be fully compliant with
the
current
release
Regulations. For general wiring configuration see
Figure 7.
The water module has been pre-wired to ensure
minimal additional work is required by the
installer. The following summarises the required
electrical connections which the installer must
make:
Primary connections, 5.9.1. A three core
cable must be connected between the supply
isolator and the cylinder connector block.
See Figure 7.
Modbus
connection,
communication cable between the cylinder
and heat pump must be installed. See Figure
8Figure 9.
Zoned connections must be wired via the
cylinder PCB, i.e. circulation pumps and/or
zone valves, 5.9.3. See Figure 9.
Temperature sensors and digital inputs can
be connected to the PCB, 5.9.4 (DI 01-05),
(NTC-DHW and NTC-Zone 1-4). See Figure
10.
of
Building
&
Wiring
5.9.2.
The
Figure 7: Primary Electrical Connections, Live, Neutral & Earth
Installation
5.9.1 Primary Electrical Connections
In both retro fit and new build installations, a 3
core cable must be taken from the isolator
[typically a 16Amp double pole fused spur] and
connected to the primary connector block as
illustrated in Figure 7.
Live connection taken from a fused spur to
the cylinder connector block, [LHS grey
terminal].
Neutral and Earth wires must be connected
to the blue and green/yellow connectors
respectively, as per Figure 7.
Note: Solid core cable or ferruled multi core
cable
must
be
used
connector block.
on
the
primary

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ecs210hp40a-580Ecs250hp40a-580

Table of Contents