5.8.1 Temperature Sensor Connection
5.8.1.1
Temperature Sensor Connection Thermostat Housing
A
Step 1: Access the sensor mounting plate. To do this remove the hood (A) by removing the fixing screws
at the bottom sides.
Position to mount sensor T3
Position to mount sensor T2
C
B
Step 2: Remove the insulation foam (B) to access the sensor mounting plate (C) and remove the M5
fixing screws in the four corners of the plate, when mounting sensor T2. If a T3 sensor is required,
remove the relay and bracket assembly first and then repeat steps for mounting sensor T2.
Installation