Emerson Rosemount OCX8800 Instruction Manual page 131

Oxygen and combustibles transmitter, hazardous location probe with integral electronics
Hide thumbs Also See for Rosemount OCX8800:
Table of Contents

Advertisement

Instruction Manual
IM-106-880C, OI
Parameter Mnemonic
COMB_PERCENT_OF_
RANGE
COMB_PREVIOUS_
CONSTANT
COMB_PREVIOUS_SLOPE
COMB_PRIMARY_VALUE
COMB_PRIMARY_VALUE_
RANGE
COMB_PRIMARY_VALUE_
TYPE
COMB_REFERENCE_
OHMS
COMB_SECONDARY_
VALUE
COMB_SECONDARY_
VALUE_RANGE
COMB_SENSOR_CAL_
DATE
COMB_SENSOR_
EXCITATION
COMB_SENSOR_TYPE
COMB_SETPOINT
COMB_SLOPE
COMB_SLOPE_WARNING
COMB_T90
COMB_TEMP_MAX
COMB_THERMOCOUPLE_
INPUT
COMB_TIME_TO_NEXT_
CAL
COMB_TOL_CHECK
COZERO_DURATION
COZERO_ENABLED
COZERO_INTERVAL
COZERO_OUTTRAK
COZERO_PURGE_TIME
COZERO_STATE
COZERO_UPDATE
DETAILED_STATUS_1
DETAILED_STATUS_2
Transducer Block Parameters
Valid Range Units
%
PPM
PPM/Ohm
See FF903
section 4.1
Ohms
mA
°
C
200-4500
PPM/Ohm
25.0-99.0
% of FS
0-300
Seconds
°C
mV
0-9999
Hours
0: No – 1: Yes
120-600
Seconds
0: Off – 1: On
Enumerated
60-480
Minutes
0, 1, 2, 3
Enumerated
60-180
Seconds
0, 1, 2
0: Off – 1: On
Enumerated
0-16777215
Bit Enum
0-16777215
Bit Enum
Description
The percent of range of the current combustibles reading.
The combustibles calibration constant from the previous good cali-
bration.
The combustibles calibration slope from the previous good
calibration.
The value and status of the combustibles concentration reading.
The High and Low range limit values, the engineering units code,
and the number of digits to the right of the decimal point for the
combustibles reading.
See FF-903 section 3.3.
The raw value of the combustibles reference input.
The combustibles cell temperature. This is the determined from the
value of the combustibles reference RTD.
The High and Low range limit values, the engineering units code,
and the number of digits to the right of the decimal point for the
combustibles cell temperature reading.
See FF-903 section 3.3.
Combustible Reference current.
See FF-903 section 3.3 and 4.3.
Combustibles heater temperature set point.
The combustibles calibration slope.
The combustible slope warning threshold.
The amount of time that the combustibles process variable will take
to reach 90% of the actual process variable.
The highest Combustibles temperature read since power on.
Combustible Block T/C voltage (Valid only with Type 3 sensor).
The time until the next automatic calibration of the combustibles
sensor.
Combustible calibration gas tolerance check.
The duration of the Combustibles sensor zero cycle.
Indicates whether Combustibles sensor zero is enabled.
The time between Combustibles sensor zero cycles.
Indicates whether the Combustibles analog output should track the
input during Combustibles sensor zero or lock at the last process
reading. (0=None, 1=O
, 2=CO
2
The duration of the Combustibles sensor zero purge.
The current step of the Combustibles sensor zero cycle. (0=Idle,
1=Flowing, 2=Purging)
Indicates whether the Combustibles calibration constants should be
updated after Combustibles sensor zero.
A bit-enumerated value used to communicate the status of the OCX.
(This is similar in nature to the command 48 status bits in HART).
A bit-enumerated value used to communicate the status of the OCX.
(This is similar in nature to the command 48 status bits in HART).
Section 7: Foundation