Energy Efficiency - IKEA LAGAN HGA4K Instruction Manual

Hide thumbs Also See for LAGAN HGA4K:
Table of Contents

Advertisement

ENGLISH
Place the label with relevant
information for new type of gas
close to the supply pipe before
sealing the appliance. If the
appliance is already sealed
please stick it directly on the user
manual booklet after Technical
data chapter close to the rating
plate drawing.
You can find this label in
package supplied with
appliance.
If the feeding gas pressure will
be different or variable,
comparing with the required, you
must install an appropriate
pressure adjuster, which is not
supplied with the product and if
needed must be ordered
separately from the local After
Sales Service (refer to the Service
chapter). The pressure adjuster
must be fitted on gas supply
pipe, in compliance with the rules
of the force.
The rating plate is located on the lower
casing of the hob.
Adjusting flame level
When hob has been fully installed, it is
necessary to check the minimum flame
setting:

Energy efficiency

Product information according to EU 66/2014
Model identification
Type of hob
1. Turn the gas tap to the maximum
position and ignite.
2. Set the gas tap to the minimum flame
position then turn the control knob from
minimum to maximum several times. If
the flame is unstable or extinguished,
follow the procedure further.
3. Re-ignite the burner and set to
minimum.
4. Remove the control knob.
5. To adjust, use a thin bladed screwdriver
and turn the adjustment screw until the
flame is steady and does not extinguish.
When the knob is turned from minimum
to maximum, and vice versa (see
following picture).
6. Repeat this procedure for all burners.
7. Reassemble the knobs.
Warning! If the appliance is
connected to liquid gas (G31
propane or G30 butane), the
regulation screw must be
fastened as tightly as possible.
17
LAGAN HGA4K
301.560.09
Built-in hob

Advertisement

Table of Contents
loading