Technical Data - IKEA LAGAN HGA4K Instruction Manual

Hide thumbs Also See for LAGAN HGA4K:
Table of Contents

Advertisement

ENGLISH
What to do if...
Problem
There is no spark when light-
ning the gas.
The flame is blowing out im-
mediately after lightning.
The gas ring burns unevenly. Burner crown is blocked with
If there is a fault, first try to find a solution to
the problem yourself. If you cannot find a
solution to the problem yourself, contact the
After Sales Service.

Technical data

Hob dimensions
Width
Depth
Built in height
Possible cause
There is no electrical supply.
There is no electrical supply.
Burner cap and crown are
placed incorrectly.
Thermocouple is not heated
enough.
food residues.
Other technical data
580 mm
500 mm
34 mm
Remedy
Check that the unit is plug-
ged in and the electrical
supply is switched on.
Check the house electric in-
stallation fuse.
Check if the burner cap and
crown have been replaced
correctly, e.g. after cleaning.
After lightning the flame,
keep the knob pushed for
about 5 seconds.
Check if the main injector is
not blocked and the burner
crown is clear of food parti-
cles.
If you operated the appliance
wrongly, or the installation was
not carried out by a registered
engineer, the visit from the
customer service technician or
dealer may not take place free
of charge, even during the
warranty period.
Class Appliance: 3
Appliance Category: II2H3+
Appliance gas supply: Natural
gas G20 (2H) 20 mbar
This appliance is designed for
use with natural gas but can be
converted for use with other gas
type according to table below.
12

Advertisement

Table of Contents
loading