N-Type Female Connectors; Table 3-3 9-Pin D-Sub Pin Connector Functions - ADC InterReach Fusion Installation, Operation And Reference Manual

Table of Contents

Advertisement

3.3.1.2
D-620610-0-20 Rev D
Table lists the function of each pin on the 9-pin D-sub connector.
9-pin D-sub Pin Connector Functions
Table 3-3
Pin
Function
1
Alarm Sense Input (DC Ground)
2
Alarm Sense Input 3
3
Alarm Sense Input 2
4
Warning Source Contact (positive connection)
5
Warning Source Contact (negative connection)
6
DC Ground (common)
7
Fault Source Contact (positive connection)
8
Alarm Sense Input 1
9
Fault Source Contact (negative connection)
This interface can both generate two source contact alarms (Fault and Warning) and
sense 3 single external alarm contacts (Alarm Sense Input 1 through 3).

N-type Female Connectors

There are two 50 Ohm N-type connector pairs for each of the 3 bands on the rear
panel of the Hub:
• The
connector receives downlink RF signals from a repeater, local
DOWNLINK
base station, or FlexWave Focus system.
• The
connector transmits uplink RF signals to a repeater, local base sta-
UPLINK
tion, or FlexWave Focus system.
CAUTION:The
UPLINK
feed from the local base station. If DC power is present, a DC block must be
used or the Fusion hub may be damaged.