Error Responses; Using The Command And Response Table; Symbol Definitions - Extron electronics SW2 USB User Manual

Usb switchers, sw usb series
Hide thumbs Also See for SW2 USB:
Table of Contents

Advertisement

Error Responses

If the switcher is unable to execute a command it receives because the command is invalid
or contains invalid parameters, the SW USB returns an error response to the host. Error
response codes and their descriptions are:
E01
E10
E13

Using the Command and Response Table

The
the responses of the switcher to the host, and descriptions of the command functions or the
results of executing the commands. The ASCII to Hex Conversion Table below is for use with
the Command and Response Table.
Space

Symbol Definitions

]
}
E = Escape key
X!
X@
X#
X$
X%
X^
NOTE:
– Invalid input channel number (out of range)
– Invalid command
– Invalid value (out of range)
Command and Response Table
ASCII to Hex Conversion Table
= CR/LF (carriage return and line feed) (hex
= Soft carriage return (no line feed)
= Space
= Input number:
0
through the maximum number of inputs (
= all inputs disconnected
0
= input 1
1
2
= input 2
= Hot key status
0
= disabled
= enabled
1
= On and off, signal, or front panel lock status
0
= Off or signal not present
= On or signal present
1
= X# X# X# X#
The X# s represent inputs 1, 2, 3, and 4 in succession.
osition of the mouse emulation DIP switch (SW4 USB Plus only)
=
P
0
= Mouse emulation off (DIP switch 1 is down.)
= Mouse emulation on (DIP switch 1 is up.)
1
= Position of the keyboard emulation DIP switch (SW4 USB Plus only)
= Keyboard emulation off (DIP switch 2 is down.)
0
= Keyboard emulation on (DIP switch 2 is up.)
1
Unless otherwise indicated, commands are not case sensitive.
on the next page lists valid ASCII command codes,
)
0D 0A
= input 3
3
4
= input 4
SW USB Series • SIS Programming and Control
2
or
4
)
24

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sw4 usb plusSw4 usb

Table of Contents