The following table lists the performance specifications of the RJ71PB91V.
Item
PROFIBUS-DP station type
Transmis
Electrical standard and characteristics
sion
Medium
specifica
Network configuration
tions
Data link method
Encoding method
Transmission speed
Transmission distance
Maximum number of repeaters (per
network)
Number of connectable modules (per
segment)
Number of connectable modules (per
network)
Maximum number of DP-Slaves
Number of connectable nodes (number of
repeaters)
Transmittable data
Number of occupied I/O points
Internal current consumption (5VDC)
External
Height
dimensio
Width
ns
Depth
Weight
*1 Transmission speed accuracy is within 0.2% (compliant with IEC61158-2).
Transmission distance
Transmission speed
9.6kbps
19.2kbps
45.45kbps
93.75kbps
187.5kbps
500kbps
1.5Mbps
3Mbps
6Mbps
12Mbps
*1 The maximum transmission distance shown in the above table indicates the distance when three repeaters are used.
To calculate the maximum transmission distance when repeaters are used and the transmission distance is extended, use the following
formula.
Maximum transmission distance [m/network] = (Number of repeaters + 1)  Transmission distance[m/segment]
2 SPECIFICATIONS
16
2.1 Performance Specifications
Description
DP-Master (Class 1)
Compliant with EIA-RS485
Shielded twisted pair cable (Page 28 Wiring for PROFIBUS cable)
Bus topology (or tree topology when repeaters are used)
• Between DP-Masters: Token passing
• Between DP-Master and DP-Slave: Polling
NRZ
*1
9.6kbps to 12Mbps ( Page 16 Transmission distance)
Varies depending on the transmission speed. ( Page 16 Transmission distance)
3
32 per segment (including repeaters)
126 per network (including DP-Master and DP-Slaves (Page 22 Configuration of PROFIBUS-
DP network))
125 (Page 22 Configuration of PROFIBUS-DP network)
32, 62(1), 92(2), 126(3)
Input data
Maximum of 8192 bytes (maximum of 244 bytes per DP-Slave)
Output data
Maximum of 8192 bytes (maximum of 244 bytes per DP-Slave)
32
0.42A
106mm (base unit mounting side: 98mm)
27.8mm
110mm
0.16kg
Transmission distance
1200m/segment
1000m/segment
400m/segment
200m/segment
100m/segment
Maximum transmission distance when
*1
repeaters are used
4800m/network
4000m/network
1600m/network
800m/network
400m/network