Download Print this page

Norcold 982F Installation Instructions Manual page 8

Upper & lower side vent installation 900 series; 9100 series; n600 series; n800 series
Hide thumbs Also See for 982F:

Advertisement

5. Pull the wires straight down from the thermostat and place a mounting plate about 12" down
from the condenser so the wires do not touch the condenser or the vertical tubing. Secure the
wires to the mounting plate with a tie wrap. Place the mounting plate under the sump and to
the left of the fan (Figure 2). Fold the excess wire as shown. Tie the folded wires to the
mounting plate under the sump with a cable tie to prevent the wires from moving by air flow.
This also prevents excess wire from getting caught between the side of the refrigerator and
theenclosure. Make sure the wires are pulled in tight between the tie wrap locations and that
the tie wraps are firmly secured.
The refrigerator is now ready for installation.
IMPORTANT: Install the refrigerator according to Norcold's installation instructions.
QTY PART NUMBER
1 ....... 618698b ............. Installation Instructions
2. ..... 61633330 ............ #8 x 3/8" Thermostat Mounting Screws
2 ...... 61581122 ............ #6 x 1 1/4" Bracket Mounting Screws
2 ........ 618951 .............. #8 x 2" Fan Mounting Screws
1 ........ 618978 .............. 6" Red Quick Connect Splice Wire #18 Gauge 4/64" Thermoplastic
1 ........ 619017 .............. 6" Black Quick connect Splice Wire #18 Gauge 4/64" Thermoplastic
2 ........ 618950 .............. Tie Rap Mounting Plate Adhesive Backed
1 ........ 619018 .............. Fan Wiring Diagram Label
1 ........ 618699 .............. 60" Red #18 Gauge Wire w/4/64" PVC Insulation, w/Quick Connect
1 ........ 618700 .............. 24" Black #18 Gauge Wire w/4/64" PVC Insulation, w/Quick Connect
1 ........ 618701 .............. 41" Red #18 Gauge Wire w/4/64" PVC Insulation, w/ Quick Connect
1 ........ 618856 .............. 12 VDC Fan (Brushless .30 Amps)
1 ........ 618093 .............. 12 VDC Thermostat (130 On / 115 Off)
1 ........ 619016 .............. Fan Support Mounting Bracket (B)
1 ........ 618857 .............. Fan Support Mounting Bracket (A)
4 ...... 61417922 ............ Cable Ties
1 ........ 619023 .............. Package Label
1 ........ 619286 .............. Thermostat Warning Note
900 / 9100 / N600 / N800 Series
Side Wall Venting Components Required
For Assembly Kit Part Number 619020
DESCRIPTION
Insulation
Insulation
Terminals, w/DC Fuse Holder
Terminals
Terminals
8