Upper & lower side vent installation 900 series; 9100 series; n600 series; n800 series
Hide thumbs Also See for 982F:

Advertisement

Upper and Lower Side Vent Installation
These instructions provide an alternative method for installing Norcold 6 and 8 cubic foot
refrigerators (see Table 1). This method allows for using two lower vents. The second lower vent
serves as the upper exhaust vent, replacing the roof vent. Use only those vents specified in the
refrigerator installation guide for side wall installation.
8 Cubic Foot Models
982F, 9182F, 982-FIM, N820F, N821F
N841F, N841-FIM
A = 62" minimum
1. Install the lower intake vent flush with the refrigerator mounting surface (see Figure 1, #1). this
location provides the necessary ventilation from outside the vehicle.
2. Install the upper exhaust vent (see Figure 1, #2) directly above the lower vent at the A
dimension, (see Figure 1 and Table 1) for the model being installed. Position this vent directly
behind the cooling unit condenser to allow heat and exhaust from the cooling unit to vent to the
outside.
Side View
Refrigerator Models
Figure 1
6 Cubic Foot Models
962F, 9162F, 962-FIM, N620F, N621F
Table 1
2
Rear View
N641F, N641-FIM
A = 55" minimum

Advertisement