11.3.1 Pre-Power Testing

Before plugging the RJ45 from the lower LPU (or if not fitted the ODU) into the PIDU, check the
following resistances at the RJ45:
1. Check the cable resistance between pins 1&2, 3&6, 4&5 and 7&8 at the RJ45. Check against
column 2 in
2. Check the cable resistance between pins 1&3 and 4&7 at the RJ45. Check against columns 3
and 4 respectively in
3. Ensure that there is greater than 100K ohms between pins 1&8 for all cable lengths.
4. Ensure that there is greater than 100K ohms between pin 1 and ODU ground for all cable
lengths.
5. Ensure that there is greater than 100K ohms between pin 8 and ODU ground for all cable
lengths.
CAT-5 Length
(Meters)
0
10
20
30
40
50
60
70
80
90
100

11.3.2 Post-Power Testing

The Correct Operation is as follows:
Table
17. Resistances for each pair should be within 1 ohm of each other.
Table
17.
Resistance
between pins 1&2,
3&6 , 4&5 and
pins 7&8 (ohms)
0.8
2.5
4.2
5.9
7.6
9.3
11.0
12.7
14.4
16.1
17.8
Table 17 Resistance Table Referenced to the RJ45 at the PIDU Plus
Lightning Protection
Resistance
between pins 1&3
(ohms)
1.0
2.7
4.4
6.1
7.8
9.5
11.2
12.9
14.6
16.3
18.0
140
Resistance
between pins 4&7
(ohms)
1.6
3.3
5.0
6.7
8.4
10.1
11.8
13.5
15.2
16.9
18.6