6.5 LED indications

The power LED for this product has a number of flashing (blinking) modes to provide status information for
diagnostics and troubleshooting.
LED color
LED code
Note: If any other LED sequence other than described above is seen and persists please contact
Raymarine technical support.
Status
Solid
Power On
Green
Green 1
Normal
blink
operation
Amber 1
Transducer
blink
disconnected
Amber 2
No network
blinks
detected
Amber 5
Under voltage
blinks
(<10.2V)
Amber 6
Over voltage
blinks
(>34.2V)
Red 1
General failure
blink
Red 3
Unit
blinks
overheating
Red 4
Problems
blinks
with internal
database
User action
• None (normal power up takes <1 minute.)
• None
• Ensure transducer cable and connections are
secure and free from damage.
• Power cycle unit to recover transducer
information.
• If problem persists contact Raymarine technical
support.
• Ensure network is powered.
• Ensure network cable and connections are
secure and free from damage.
• If problem persists contact Raymarine technical
support.
• Ensure power cable and connections are secure
and free from damage.
• Ensure power supply cabling is consistent with
recommendations.
• If problem persists contact Raymarine technical
support.
• Ensure power supply levels are consistent with
recommendations.
• If problem persists contact Raymarine technical
support.
• If combined with voltage warning, check power
supply and cables.
• Power-cycle the unit.
• If problem persists contact Raymarine technical
support.
• Ensure installation environment is within
recommendations.
• Unit will stop pinging and then start again once
normal operating temperature is achieved.
• If problem persists contact Raymarine technical
support.
• Power-cycle the unit.
• If problem persists contact Raymarine technical
support.