General Cabling Guidance - Raymarine CP200 Installation Instructions Manual

Table of Contents

Advertisement

4.1 General cabling guidance

Cable types and length
It is important to use cables of the appropriate type
and length
• Unless otherwise stated use only standard cables
of the correct type, supplied by Raymarine.
• Ensure that any non-Raymarine cables are of the
correct quality and gauge. For example, longer
power cable runs may require larger wire gauges
to minimize voltage drop along the run.
Routing cables
Cables must be routed correctly, to maximize
performance and prolong cable life.
• Do NOT bend cables excessively. Wherever
possible, ensure a minimum bend diameter of 200
mm (8 in) / minimum bend radius of 100 mm (4 in).
200 mm (8 in)
• Protect all cables from physical damage and
exposure to heat. Use trunking or conduit where
possible. Do NOT run cables through bilges or
doorways, or close to moving or hot objects.
• Secure cables in place using tie-wraps or lacing
twine. Coil any extra cable and tie it out of the way.
• Where a cable passes through an exposed
bulkhead or deckhead, use a suitable watertight
feed-through.
• Do NOT run cables near to engines or fluorescent
lights.
Always route data cables as far away as possible
from:
• other equipment and cables,
• high current carrying ac and dc power lines,
• antennae.
Caution: Pulling cables
Do NOT use cords or ropes, attached
to cable connectors, to pull cables
through restricted apertures (e.g. as in
bulkheads), as this could cause damage
to cables.
Strain relief
Ensure adequate strain relief is provided. Protect
connectors from strain and ensure they will not pull
out under extreme sea conditions.
Circuit isolation
Appropriate circuit isolation is required for
installations using both AC and DC current:
• Always use isolating transformers or a separate
power-inverter to run PC's, processors, displays
100 mm (4 in)
and other sensitive electronic instruments or
devices.
• Always use an isolating transformer with Weather
FAX audio cables.
• Always use an isolated power supply when using
a 3rd party audio amplifier.
• Always use an RS232/NMEA converter with
optical isolation on the signal lines.
• Always make sure that PC's or other sensitive
electronic devices have a dedicated power circuit.
Cable shielding
Ensure that all data cables are properly shielded
that the cable shielding is intact (e.g. hasn't been
scraped off by being squeezed through a tight area).
Cable ferrite installation
Your product may be supplied with cable ferrites. To
ensure EMC Compliance, any supplied ferrites must
be fitted to the cables according to the following
instructions.
1
2
3
1. RayNet cable.
2. Fit 2 ferrites to the RayNet cable. There should
be no gap between the 2 ferrites.
3. Secure the ferrites in place using the supplied
cable ties.
4. Power cable.
5. Fit 2 ferrites to the power cable. There should be
no gap between the 2 ferrites.
6. Secure the ferrites in place using the supplied
cable ties.
7. Ensure the distance between the end of the last
ferrite and the top of the connector is no more
than 200 mm (7.87 in).
Note: If the ferrites are supplied in different sizes,
ensure that you select the correct size for the
appropriate cable. This is confirmed by a tight fit.
4
7
5
6
D13014-1
CP100 / CP200

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp100

Table of Contents