Heater
Leads
Figure 21
Orifice Gasket
Compression
Ring
Compression
Nut
Figure 22
Suspension Wire
Flue Baffle
Figure 23
11. Disconnect the heater leads.
12. Remove the drain cup.
13. Remove the 1/4" screw that secures the burner
Burner
Cover
14. Loosen the burner tube compression nut and
Orifice
15. Remove the orifice and orifice gasket from the
16. Remove the burner from the cooling unit.
17. Remove the thermocouple and ignition electrode
18. Remove the cooling unit from the cabinet. Pull
Installation of New Cooling Unit
Figures 23-30
1. Inspect the replacement cooling unit for physical
2 Inspect the evaporator tubes to insure that they
2. Check for the presence of the flue baffle. Do not
3. Check heating element for correct resistance.
19
cover to the cooling unit and remove the burner
cover.
remove the burner tube from the burner. Care-
fully pull the burner tube forward and away to
allow clearance when removing the cooling unit.
burner. Do not misplace the orifice and orifice
gasket. These components are to be used for
reassembly.
from the bracket of the cooling unit. The thermo-
couple should be pulled forward and away to
allow clearance when removing the cooling unit.
the cooling unit away from the cabinet with a
steady pressure until it is free.
damage when removing from carton. Remove
any foam from the evaporator tubes.
are clean and free from debris.
install without baffle.
Refer to figure 9 on page 14 for procedure.