Pfaff 3371-1 series Adjustment Manual page 38

Hide thumbs Also See for 3371-1 series:
Table of Contents

Advertisement

Adjustment
Group
14 - 35
Parameter
Description
600
607
Cold start (RESET)
With this function the control unit
carries out a cold start (RESET) with
which the data is reset. After this
function has been selected, the
machine must be switched off and
then on again.
608
Setting zero points
With this function and the adjustment
gauge, the zero points for the X/Y-drive
unit can be set. (stepping motor
correction values for the reference
points REFX, REFY). The access code
is required for this adjustment.
609
Setting the clamp centre X
This function is used to set the centre
of the clamp in X-direction. When
entering the function, the machine
moves to the current clamp centre,
after which it is possible to move to
the right or left edge of the clamp,
depending on the set limits (param.
"023"). A correction can be made with
the plus/minus keys. The relocation
value is displayed.
610
Setting the clamp centre Y
This function is used to help set the
centre of the clamp in Y-direction. After
entering this function, the machine
moves to the current clamp centre,
after pressing a key to the front or the
rear limit (param. "024"). The clamp
must be shifted manually.
611
Automatic clamp opening off
With this function the automatic
opening of the clamp after thread
trimming can be switched off. After
the machine has been switched off,
the automatic clamp opening function
is always activated.
612
Test function continuous start
Setting
Set value
range
ON - OFF
OFF
ON - OFF
OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents