Pfaff 3371-1 series Adjustment Manual page 35

Hide thumbs Also See for 3371-1 series:
Table of Contents

Advertisement

Group
Parameter
Description
000
017
Clamp solenoid
Operating time [10 ms]
The time, for which the solenoid is
under full current, is entered.
018
Clamp solenoid duty-cycle [%]
At the end of the clamp solenoid
operating time (Parameter "017") the
solenoid is clocked. The relationship
between duration of operation and
non-operation is entered here.
019
Thread trimming solenoid operating
time [10 ms]
The time, for which the solenoid is
under full current, is entered.
020
Thread trimming solenoid duty-cycle
At present without a function
021
Thread take-up lever t.d.c. [°]
The position for the t.d.c. thread
take-up lever is entered here. If the
function is executed, the position can
be set by turning the balance wheel.
The access code is necessary for this
adjustment.
022
Thread trimming position
(in relation to t.d.c. needle) [°]
The position, at which the thread
trimming solenoid is switched on, is
entered here. The adjustment is set
by turning the balance wheel.
The access code is necessary for this
adjustment.
023
Sewing area size X [1/10 mm]
To avoid mechanical collisions, the
sewing area size of the clamp in use
is entered. The control unit checks
the path and, if necessary, issues an
error message.
024
Sewing area size Y [1/10 mm]
To avoid mechanical collisions, the
sewing area size of the clamp in use
is entered. The control unit checks the
path and, if necessary, issues an error
message.
Adjustment
Setting
Set value
range
5 – 100
10
5 – 100
20
5 – 100
25
5 – 100
100
45 – 53
51
180 – 253
180
±200
-100 / +200
±100
-15 / +15
14 - 32