Port Safety Classification; Compliance With Fcc Rules - Avaya IP OFFICE 40DHB0002USCL Installation Manual

Avaya ip phone user manual
Table of Contents

Advertisement

Page 66 - Port Safety Classification

Port Safety Classification

The Avaya IP Office systems have the following ports:
• Expansion ports
• 10/100 BaseT LAN ports
• Telephone ports which are either DT (A-Law encoding) or DS (µ-Law encoding)
• ISDN ports
• Analog ports
• Power Fail ports
• WAN ports
• DTE ports
• Audio I/P port
• DC Power Input port
• External Control port
These Ports are classified as follows:
Port Name
PRI port
BRI ports
Analog ports
Power fail ports
DTE port
Telephone Ports
WAN port
LAN ports
Expansion ports
Audio port
External Control port
DC Input port
Interconnection circuits shall be selected to provide continued conformance with the requirements of
EN 609050:1992/A3:1995 clause 2.3 for SELV circuits and with the requirements of clause 6 for TNV
circuits, after connections between equipment.

Compliance with FCC Rules

Transmit and Receive Gain Settings for PRI/T1 and Analog Ports
The Gain settings are password controlled for use by qualified installation personnel only and must
not be made available to the end user. The default gain settings of 0dB ensures compliance with
FCC part 68 section 68.308(b)(5) and TIA/EIA-IS-968 Section 4.5.2.5. "Through transmission
amplification from ports for the connection of separately registered equipment or from other network
connection ports". Gain setting adjustment by unqualified personnel may result in violation of the
FCC rules. Qualified personnel may adjust gain settings above these levels only where:
1. Measurement is made to ensure that the power levels sent to line at each network interface
connected does not exceed the maximum levels specified in FCC part 68 section 68.308(b) and
TIA/EIA-IS-968 Section 4.5 for that specific interface type.
2. Where gain adjustment away from the default values are made, precautions should be taken to
ensure that the connection of terminal equipment is controlled by qualified installation personnel.
Page 66 - Technical Data
Port Safety Classification
Port Description
PRI ISDN connection (NET)
BRI ISDN connection (NET)
Two wire analog trunk
Two wire analog trunk
Async Data connection.
Telephone Extension ports
WAN connection (NET).
10/100 BaseT attachment to LAN.
Expansion Module connector.
Connector for Music on Hold.
Connector for Controlling Ancillary circuits.
Connector for DC input power.
Port Classification
TNV (Operating within the limits of SELV)
TNV (Operating within the limits of SELV)
TNV3
TNV3
SELV
TNV2
SELV
SELV
SELV
SELV
SELV
SELV