Nordyne O4HD-091A-14-FA-DV Installation, Operation And Maintenance Manual page 16

Oil fired warm air furnaces
Table of Contents

Advertisement

Table A-10 ECM Blower
Set-Up (O4HD-091A-V-FA)
DIP SWITCH ADJUSTMENT
CHART
FOR INPUT 0.50 USGPH TO 0.75 USGPH
SW1 - HEAT
DIP Switch
Position
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
POS.
A
B
C
D
INPUT
USGPH
0.65
N/A
0.75
0.50
SW3 - ADJUST
DIP Switch
Position
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
POS.
A
B
C
D
CFM
O%
(+)15%
(415%
N/A
SW2 - COOL
DIP Switch Position
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
POS.
A
B
C
D
AC Size
(TON)
3
2.5
2
1.5
SW4 - DELAY
DIP Switch Position
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
POS.
A
B
C
D
INPUT
USGPH
0.65
N/A
0.75
0.50
NOTE:
SWl
(HEAT)
AND SW4 (DELAY)
DIP SWITCHES
MUST BOTH BE ADJUSTED
ACCORDING
TO INPUT (NOZZLE
SIZE).
SW2 (COOL):
1 TON is approximately
equal to 400 CFM
SW3 (ADJUST):
(Heating
Mode)
Increase
OR decrease
temperature
rise respectively
(Cooling
Mode)
Increase
OR decrease
CFM respectively
16