Nordyne O4HD-091A-14-FA-DV Installation, Operation And Maintenance Manual page 13

Oil fired warm air furnaces
Table of Contents

Advertisement

Furnace
Model
Table A-6 Direct Drive Blower Set-Up
PSC Motor
Blower Set-Up
Cooling
Capacity
0.20 in. w.c.
0.50 in. w.c.
CFM
Blower
Speed
Motor
Speed
Motor
Tons
Power
Range
O4HD-070A-12-FB
O4HD-070A-14-FA-DV
O4HD-091A-12-FB
O4HD-091A-14-FA-DV
O4HD-105A-12-FB
O4H D-105A-14-FA-DV
100-10T
DD
100-10T
DD
100-10T
DD
Low
Med-Low
Med-
High
1/2 HP
1/2 HP
1/2 HP
Med-Low
Med-High
High
1/2 HP
1/2 HP
1/2 HP
1/2 HP
1/2 HP
1/2 HP
690 - 1500
690 - 1500
690 - 1500
Furnace
Model
Table A-7 Direct Drive Blower Characteristics
PSC Motor
Blower
Motor
HP
Motor
FLA
AT
Speed
CFM
External
Static Pressure
- Inches w.c.
0.2
0.3
0.4
0.5
0.6
O4HD-A-12-FB
O4HD-14-FA-DV
070-105
100-10T
DD
1/2 HP
7
60°F
High
1741
1651
1556
1476
1369
Med-
1557
1497
1434
1369
1278
High
Med-
1063
1051
1037
1037
1011
Low
Low
697
697
687
672
646