Ad.rate Enter Analog To Digital Rate Submenu; Mode Enter Input Mode Configuration Submenu; Table 16-1 A/D (Analog To Digital) Rate Option Table - Omega DP41-B User Manual

Universal input meter
Hide thumbs Also See for DP41-B:
Table of Contents

Advertisement

16
Input Configuration Menu
16.2 Ad.RAtE
Press 'RESET/ENTER'
Press ' /MAX'
Rate
Time for 60hz(ms)
Time for 50Hz(ms)
Table 16-1. A/D (Analog to Digital) Rate Option Table
Press 'RESET/ENTER'
16.3 MOdE
INP.CNF
(Input Configuration )
60
Enter ANALOG TO DIGITAL RATE SUBMENU:
7) Display flashes "0" or previous selection.
8) Scroll through the 6 available selections as 0, 1, 2, 3, 4, and 5 for
your choice of selection. Refer to below Table for your specific application
conversion speed. Only Rate 0 and 1 can reject 60 Hz / 50 Hz noise.
Refer to Table 33-1 in Specification Section for different input and outputs types.
0
134.9
161.9
9) Display advances to "MOdE" Input Mode Configuration Submenu. If a
change was made, the controller will also show "StOREd" stored
message momentarily.
Enter INPUT MODE CONFIGURATION SUBMENU:
This submenu is only accessible if "tC" Thermocouple or "bRIdGE"
Bridge is your selection of input type.
LIN.FRE
(Line Frequency & Hz)
Ad.RAtE
0
(Analog to Digital Rate)
MOdE
tC.CO.JC
Accessible IF
Yes
your INPUT selection:
(Thermocouple
TC
Cold Junction)
No
Accessible IF
Yes
bRdG.LM
your INPUT selection:
(Bridge Limit)
bRIdGE
No
RAtIO
(Strain Ratio)
IN.SC.OF
(Input Scale & Offset)
1
2
68.2
34.9
81.9
41.9
60
50
1
2
3
4
5
ENAbLE
dISAbL
NORMAL
SP1.L.2.H
ENAbLE
dISAbL
3
4
5
18.2
9.9
5.7
21.9
11.9
6.9
C.JUN.OF
(Field Calib.)
SP1 value > lower overload limit.
SP2 value < upper overload limit.
DISAbL
ENAbLE
CAL 0