13
Reading Configuration Menu Flowchart
13 READING CONFIGURATION MENU and FLOWCHART: (RdG.CNF)
RdG.CNF
Rd.SC.OF
(Reading Scale & Offset)
UNt.tMP
(Temperature Unit)
dEC Pt
(Decimal Point)
FILtER
FLS.dSP
(Flashing Display)
bRIGHt
(Brightness)
50
dIRECt
ENAbLE
2.C d INt
(2 coordinate formula)
dISAbL
Offset=0
Scale=1
C
F
k
yES
dP.ACt V
(Decimal Point Active)
NO
SEt dP
(Decimal Point Setting)
FFFFFF
FFFFF.F
FFFF.FF
FFF.FFF
FF.FFFF
F.FFFFF
CNt by
001
(Count By)
(Adaptive Bandwidth Control Filter)
FILt.tP
(Filter Type)
FILt.tM
001
(Filter Time)
SP1.FLS
(Setpoint Flashing)
SP2.FLS
AL1.FLS
(Alarm 1 Flashing)
AL2.FLS
H.bRt
M.bRt
L.bRt
RdG SC
RdG OF
ON.LINE
INPUt 1
(Input 1 value)
REAd 1
(Read 1 value)
INPUt 2
(Input 2 value)
REAd 2
(Read 2 value)
002
005
010
020
050
A.b.C.FIL
MOV.AVE
(Moving Average)
002
004
008
016
032
ENAbLE
dISAbL
ENAbLE
dISAbL
ENAbLE
dISAbL
ENAbLE
dISAbL
(value)
(value)
MANUAL
INPUt 1
(Input 1 value)
REAd 1
(Read 1 value)
INPUt 2
(Input 2 value)
REAd 2
(Read 2 value)
100
064
128