Installation
Preparation
ADVANCE PLANNING
Duct Install
Planning
. This hood is designed to be vented vertically
through
the ceiling. Use a 6" round duct. Use
locally supplied elbows to vent horizontally
through
the rear wall.
. Use metal ductwork
only.
. Determine
the exact locution of the vent hood.
. Plan the route for venting exhaust to the
outdoors. To maximize the ventilation
performance
of the vent system:
1. Minimize the duct run length and number of
transitions
and elbows.
2. Maintain a constant
duct size.
3.Seal all joints with duct tape to prevent any
leaks.
4. Do not use any type of flexible ducting.
. Install a wall cap or roof cap with damper
at the exterior opening. Purchase the wall or
roof cap and any transition
and length of duct
needed in advance.
. When applicable,
install any makeup
(replacement)
air system in accordance
with local building code requirements.
Visit
GEAppliances.com
for available
makeup air
solutions.
Recirculation Install Planning
A recirculation duct (included) and two
charcoal filters (not included) are necessary for
recirculation installation.
Power Supply Planning
The location of the power supply connection
is
called out in the Prepare the Wall section on
page 6.
POWER SUPPLY
IMPORTANT-
(Please read carefully}
AWARNING:
FOR PERSONAL SAFETY,THIS APPLIANCE MUST BE
PROPERLYGROUNDED.
Remove house fuse or open circuit breaker
before beginning
installation.
Do not use an extension
cord or adapter
plug
with this appliance.
Follow National Electrical
Codes or prevailing
local codes and ordinances.
Electrical
supply
These vent hoods must be supplied with 120V,
60Hz, and connected
to an individual,
properly
grounded
branch circuit, and protected
by a 15
or 20 amp circuit breaker or time delay fuse.
. Wiring must be 2 wire with ground.
. If the electrical supply does not meet the above
requirements,
call a licensed electrician
before
proceeding.
. Route house wiring as close to the installation
location as possible in the ceiling or wall.
. Connect the wiring to the house wiring in
accordance
with local codes.
Grounding
instructions
The grounding conductor
must be connected to
a ground metal, permanent
wiring system, or an
equipment-grounding
terminal or lead on the hood,
,WARNING:
The improper connection
of the equipment-grounding conductor can result
in a risk of electric shock. Check with a qualified
electrician or service representative if you are in
doubt whether the appliance is properly grounded.
!