Instruction Manual
D200149X012
Table 1. Specifications (Continued)
Declaration of SEP
Fisher Controls International LLC declares this
product to be in compliance with Article 4 paragraph
3 of the PED Directive 2014/68/EU. It was designed
and manufactured in accordance with Sound
NOTE: Specialized instrument terms are defined in ANSI/ISA Standard 51.1 - Process Instrument Terminology.
1. For direct action, an increasing input signal extends actuator rod. For reverse action, an increasing input signal retracts actuator rod.
3
2. Normal m
/hr—Normal cubic meters per hour (0_C and 1.01325 bar, absolute). Scfh—Standard cubic feet per hour (60_F and 14.7 psia).
3. The pressure and temperature limits in this document, and any applicable code or standard should not be exceeded.
Table 2. Fisher 3622 Electro‐Pneumatic Converter
Port
Electrostatic Discharge (ESD)
Radiated EM field
Enclosure
Rated power frequency magnetic field
Burst
Surge
I/O signal/control
Conducted RF
Specification limit = ±1% of span
1. The information contained in the table also applies to 3620J, 3620JP, and 3621JP electro‐pneumatic positioners.
2. A=No degradation during testing. B = Temporary degradation during testing, but is self‐recovering.
Table 3. Typical Performance Specifications
Characteristic
(1)
Deadband
(1,4,5)
Step Response
(6,7)
Steady‐State Air Consumption
(3)
Hysteresis
(8)
Terminal‐Based Linearity
(1)
Frequency Response
(-6 dB)
Supply Pressure Sensitivity
1. Performance tests are based on 6.9 bar (100 psig) supply pressure and lightest actuator springs. Performance will vary with other pressures and springs.
2. Size 25 and 50 actuators tested with appropriate parallel flexure (key 179).
3. Equipped with two 2625 boosters with 1/2 inch supply and exhaust ports.
4. Step response is the time for the actuator to reach 63 percent of expected travel after a 10 percent step change in input signal.
5. 3621JP positioner step response equals 0.4 seconds.
6. At 6.9 bar (100 psig) supply pressure. Normal m
7. 3621JP positioner steady‐state air consumption equals 0.02 normal m
8. 3621JP positioner terminal‐based linearity equals ±2.25%.

Type Number Description

The following descriptions provide specific information on the different positioner constructions. If the type number is
not known, refer to the nameplate on the positioner. For the nameplate location, refer to key 157, figure 25.
3610J: A single‐acting pneumatic rotary valve positioner for use with Fisher 1051, 1052, and 2052 actuators.
3610JP: A double‐acting pneumatic rotary valve positioner for use with Fisher 1061 and 1069 actuators.
3611JP: A double‐acting pneumatic sliding stem valve positioner for use with 585, 585R, 585C, and 585CR actuators.
3620J: A single‐acting electro‐pneumatic rotary valve positioner for use with 1051, 1052, and 2052 actuators.
Phenomenon
(1)
for Fisher 3611JP and 3621JP Positioners with 585, 585R, 585C, and 585CR Actuators
585C and 585CR
(2)
Size 25 Actuator
0.1% of input span
0.3 seconds
3
0.01 normal m
/min
(0.4 scfm)
0.5% of output span
1% of output span
2 Hz
10% change in supply pressure changes the actuator stem position less than 0.1%
3
/min‐cubic meters per minute (0_C and 1.01325 bar). Scfm‐‐standard cubic feet per minute (60_F and 14.7 psia).
3
/min (0.58 scfm).
Engineering Practice (SEP) and cannot bear the CE
marking related to PED compliance.
However, the product may bear the CE marking to
indicate compliance with other applicable European
Community Directives.
(1)
EMC Summary Results—Immunity
Basic Standard
IEC 61000‐4‐2
4 kV contact; 8 kV air
80 to 1000 MHz @ 10V/m with 1 kHz AM at 80%
IEC 61000‐4‐3
1400 to 2000 MHz @ 3V/m with 1 kHz AM at 80%
2000 to 2700 MHz @ 1V/m with 1 kHz AM at 80%
IEC 61000‐4‐8
60 A/m at 50 Hz
IEC 61000‐4‐4
1 kV
IEC 61000‐4‐5
1 kV (line to ground only, each)
IEC 61000‐4‐6
150 kHz to 80 MHz at 3 Vrms
585C and 585CR
(2)
Size 50 Actuator
0.1% of input span
0.1% of input span
0.3 seconds
2 seconds
3
0.01 normal m
/min
0.01 normal m
(0.4 scfm)
(0.4 scfm)
0.5% of output span
0.5% of output span
1% of output span
1% of output span
2 Hz
0.2 Hz
3610J and 3620J Positioners
Test Level
585 and 585R
Size 100 Actuator Standard
3
/min
September 2017
Performance
(1)
Criteria
A
A
A
A
B
A
585 and 585R
Size 100 Actuator with
(3)
Boosters
0.1% of input span
0.3 seconds
3
0.01 normal m
/min
(0.4 scfm)
0.5% of output span
1% of output span
2 Hz
5

Hide quick links: