Parameter
Description
U349*
Sample&Hold element
SH3 Time Slot
Parameter for entering the slower time slot
2349
U350*
BICO parameter for selecting the binector for enabling the
S.TeCntr Rel

technology controller.

2350
U351
Parameter for entering the controller type of the
TeCntr RegType
technology controller.
0 = Normal PID controller
2351
1 = PI controller with D component in actual-value channel
U352*
BICO parameter for selecting the connector for the
S.TeCntr Setp
setpoint of the technology controller.
2352
U353
Parameter for entering the setpoint smoothing time
TeCntr SetpSmth
constants of the technology controller.
2353
n354
Visualization parameter, smoothed setpoint of the
TeCntr Setp
technology controller.
2354
U355*
BICO parameter for selecting the connector for the actual
S.TeCntr ActV
value of the technology contoller.
2355
n356
Visualization parameter, actual-value of the technology
TeCntr ActV
controller.
2356
n357
Visualization parameter, set/actual value deviation of the
TeCntr Deviation
technology controller with the "PID controller" type. The
inverted actual value is displayed on the "PI controller with
2357
D component in actual-value channel" controller type.
U358
Parameter for entering the actual-value smoothing time
TeCntr ActVSmth
constants of the technology controller.
2358
Siemens AG
6SE7087-6QX70 (Edition AG)
SIMOVERT MASTERDRIVES Compendium Motion Control
Data
Read/write
Init: 2
Menus:
Min: 2
- Parameter menu
Max: 10
+ Free blocks
Unit: -
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,B
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 1
Menus:
Min: 0
- Parameter menu
Max: 1
+ Free blocks
Unit: -
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Init: 0,00
Menus:
Min: 0,00
- Parameter menu
Max: 60,00
+ Free blocks
Unit: s
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
Dec.Plc.: 1
Menus:
Unit: %
- Parameter menu
Indices: -
+ Free blocks
Type: I2
- Upread/free access
Init: 0
Menus:
Unit: -
- Parameter menu
Indices: -
+ Free blocks
Type: L2 ,K
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
Dec.Plc.: 1
Menus:
Unit: %
- Parameter menu
Indices: -
+ Free blocks
Type: I2
- Upread/free access
Dec.Plc.: 1
Menus:
Unit: %
- Parameter menu
Indices: -
+ Free blocks
Type: I2
- Upread/free access
Init: 0,00
Menus:
Min: 0,00
- Parameter menu
Max: 60,00
+ Free blocks
Unit: s
- Upread/free access
Indices: -
Changeable in:
Type: O2
- Ready to switch on
- Operation enabled
159