Flow Data & Injector Draw Rates - Pentair Fleck 2900S Service Manual

Hide thumbs Also See for Fleck 2900S:
Table of Contents

Advertisement

TR22089-2900s Valve 1600 Series Injector Draw Rates
TR22089-2900s Valve 1600 Series Injector Slow Rinse Rates
2.40
2.20
2.00
1.80
1.60
1.40
1.20
1.00
0.80
0.60
0.40
0
10
20
30
40
50
60
Inlet Pressure - psi
# 2
1600
Slow Rinse Rates - gpm
series injectors
pressure
20
0.68
30
0.77
40
0.86
60
1.00
90
1.19
125
1.38
all injectors used the steel cap and an air disperser
TR22089-2900s Valve 1600 Series Injector Total Flow to Drain in Draw
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0
10
20
30
40
50
60
Inlet Pressure - psi
# 2
70
80
90
100
110
120
130
140
# 3
# 4
0.78
1.08
0.97
1.28
1.09
1.50
1.27
1.63
1.52
1.93
1.76
2.20
70
80
90
100
110
120
130
140
# 3
# 4
TR22089-2900s Valve 1700 Series Injector Slow Rinse Rates
10.5
10.0
9.5
9.0
8.5
8.0
7.5
7.0
6.5
6.0
5.5
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0
10
20
30
40
50
60
Inlet Pressu re - psi
# 3C
# 4C
1700 series injectors
Slow Rinse - gpm
pressure
# 3C
# 4C
20
0.93
1.84
30
1.06
2.19
40
1.18
2.40
60
1.42
2.80
90
1.64
3.34
125
1.90
3.88
# 3C - steel cap, no o-ring, air disperser
# 4C & 5C - steel cap, o-ring, air disperser
# 6C & 7C - brass cap, o -ring, no air disperser
TR 22089 - 2900s valve 1700 Series Injector Draw Rates
3.3
3.1
2.9
2.7
2.5
2.3
2.1
1.9
1.7
1.5
1.3
1.1
0.9
0.7
0.5
0
10
20
30
40
50
60
Inlet Pressure - psi
# 3C
# 4C
TR22089-2900s Valve 1700 Series Injector Total Flow to Drain in Draw
14.0
13.0
12.0
11.0
10.0
9.0
8.0
7.0
6.0
5.0
4.0
3.0
2.0
1.0
0
10
20
30
40
50
60
Inlet Pressure - psi
# 3C
# 4C
70
80
90
100
110
120
130
140
# 5C
# 6C
# 5C
# 6C
2.34
3.13
2.82
3.70
3.14
4.12
3.68
4.82
4.35
5.70
5.00
6.58
70
80
90
100
110
120
130
140
# 5C
# 6C
70
80
90
100
110
120
130
140
# 5C
# 6C

Advertisement

Table of Contents
loading