Emerson Rosemount5081 Instruction Manual page 16

Explosion-proof transmitter
Table of Contents

Advertisement

Description and specifications
Explosion proof certification
Certification conditions
Intrinsic safety certification
Certification conditions
Non incendive certification
Certification conditions
Certification standards
FM
Explosion proof certification
Certification conditions
Dust ignition proof certification
Certification conditions
Intrinsic safety certification
6
Class I, Division 1, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class III
T6 T
max. 70 °C
amb
4X enclosure type
Seal required at each conduit entry
Class I, Division 1, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class III
T4 T
max. 70 °C
amb
4X enclosure type
For Intrinisically Safe installation, see drawings 1400674 or
1400675.
Class I, Division 2, Groups A, B, C, D
Class II, Division 2, Groups E, F, G
Class III
T4 T
max. 70 °C
amb
4X enclosure type
For Non-Incendive Field Wiring installation, see drawings
1400674 or 1400675
CSA standards: 22.2 No. 0-M1987, 22.2 No. 142-M1987, 22.2 No.
157-921, 22.2 No. 213-M1987
Class I, Division 1, Groups B, C, D
T6 T
max. 70 °C
amb
4X enclosure type
Install per control drawing 1400678 or
1400679.
Class II & III, Division1, Groups E, F, G
T6 T
max. 70 °C
amb
Install per control drawing 1400678 or
1400679.
Class I, Division 1, Groups A, B, C, D
Class II, Division 1, Groups E, F, G
Class III, Division 1
T4 T
max. 70 °C
amb
4X enclosure type
Rosemount 5081

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents