Download Print this page

Icom iR8600 Reference Manual page 23

Communications receiver

Advertisement

Remote control
D Command formats (Continued)
 Center/Fixed mode settings
Command: 27 14
0 0 X X
00 : Ce n ter m o d e
01 : F ixe d mo d e
00 (Fixed)
 Scope span settings (Only in the Center mode)
Command: 27 15
q
w
e
r
t
0 0
0 0 X X
X X 0 X 0 0
 Scope Hold settings
Command: 27 17
0 0 X X
00: Hold function OFF
01: Hold function ON
00 (Fixed)
 Scope Reference level settings
Command: 27 19
0 0 X X X 0 X X
LAdjustable range: –20.0 dB ~ +20.0 dB (in 0.5 dB steps)
y
Span (Hz)
2500
2.5k
5000
10000
10k
25000
25k
50000
50k
100000
100k
250000
250k
500000
500k
1000000
1.0M
2500000
2.5M
00:+
01:–
 Sweep speed settings
Command: 27 1A
0 0 X X
00 (Fixed)
 VBW (Video Band Width) settings
Command: 27 1D
0 0 X X
5k
00 (Fixed)
 Fixed edge frequency settings
Command: 27 1E
q
w
e
r
0 1
0 1 X
X X X X X X X X X X X X X X X X X X X
Edge frequency (Lower) Edge frequency (Upper)
22
00: FAST
01: MID
02: SLOW
00: Narrow
01: Wide
t
y
u
i
o
!0
!1
!2

Advertisement