Yamaha YSP-4300 Service Manual page 118

Hide thumbs Also See for YSP-4300:
Table of Contents

Advertisement

A
B
YSP-CU4300/YSP-CU3300/NS-WSW160
1
POWER (1)
(Side A)
2
3
CB1
AC IN
4
5
U, C, V, S, J models
6
Notes)
Safety measures
Some internal parts in this product contain high voltages and are dangerous. Be sure to take safety measures during servicing, such
as wearing insulating gloves.
Note that the capacitors indicated below are dangerous even after the power is turned off because an electric charge remains and a
high voltage continues to exist there. Before starting any repair work, connect a discharging resistor (5 k-ohms/10 W) to the terminals
7
of each capacitor indicated below to discharge electricity. The time required for discharging is about 30 seconds per each.
C8, C44 and C48 on POWER (1) P.C.B.
118
C
D
T, K, A, B, G, F, L, H models
5 k-ohms
10 W
注意)
安全対策
・ この製品の内部には高電圧部分があり危険です。修理の際は、絶縁性の手袋を使用するなどの安全対策を行ってください。
・ 下記のコンデンサには電源を OFF にした後も電荷が残り、高電圧が維持されており危険です。修理作業前に放電用抵抗(5
E
F
YSP-CU4300
YSP-CU3300
U, C, V, S, J models
U, C, V, S, J models
T, K, A, B, G, F, L, H models
k Ω /10 W)を下記の各コンデンサの端子間に接続して放電してください。放電所用時間は各々約 30 秒間です。
POWER(1)P.C.B. の C8、C44、C48
G
H
I
AW_RPT
AW_PON
S6.3
SGND
DIGITAL
SGND
(CB106)
SGND
S3.3
S3.3
INPUT (3)
(CB72)
INPUT (4)
(W63)
5 k-ohms
10 W
YSP-CU4300
CB4
CB7
W3
IC12
IC11
5
1
5
1
+26D
+26D
DAMP
DGND
(CB910)
DGND
+12D
J
DAMP
(CB913)
(YSP-CU4300)
DIGITAL
(W303)
P_CON
AC_PWR_DWN
26V_PRI
+3.3D
+3.3D
DGND
DGND
DGND
+12D
+12D
S3.3
DGND
DGND
+3.3D
DGND
+26D
INPUT (1)
(CB6)
• Semiconductor Location
Ref no. Location
Ref no. Location
D1
C4
IC2
E4
D3
E4
IC3
D3
IC4
F3
D4
E4
D7
F4
IC6
F3
D8
F5
IC7
D3
D9
F4
IC11
H5
D14
E3
IC12
H5
D20
G4
Q2
E4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ysp-3300Ns-wsw160Ysp-cu4300Ysp-cu3300

Table of Contents