9.1.4

Data sets

Example of data set assignment
Table 9- 2
DDS
DDS 0
DDS 1
DDS 2
DDS 3
9.1.4.1

Integration

Function diagrams (see the SINAMICS DCM List Manual)
● 8560 Command data sets (CDS)
● 8565 Drive data sets (DDS)
● 8570 Encoder data sets (EDS)
Overview of important parameters (refer to the SINAMICS DCM List Manual)
Adjustable parameters
● p0140 Encoder data sets (EDS) number
● p0170 Command data sets (CDS) number
● p0180 Drive data sets (DDS) number
● p0187 Encoder 1 encoder data set number
● p0188 Encoder 2 encoder data set number
● p0809 Copy command data set (CDS)
● p0810 BI: Command data set CDS bit 0
● p0819[0...2] Copy drive data set DDS
● p0820 BI: Drive data set selection DDS, bit 0
● p0821 BI: Drive data set selection DDS, bit 1
CDS: Command data set
The BICO parameters (binector and connector inputs) are grouped together in a command
data set. These parameters are used to interconnect the signal sources of a drive.
By parameterizing several command data sets and switching between them, the drive can
be operated with different pre-configured signal sources.
A command data set contains the following (examples):
SINAMICS DCM Control Module
Operating Instructions, 06.2010, C98130-A7067-A1-02-7619
Example, data set assignment
Encoder 1 (p0187)
EDS 0
EDS 0
EDS 0
EDS 1
9.1 Basic information
Encoder 2 (p0188)
EDS 1
EDS 0
EDS 0
-
Operation