9. Adjust pressure setting to the minimum value
(Tab. 1 below) adjusting screw on modulating
valve (Fig.6).
MIN
GAS
Continuum 11i (11i-fp)
G20
NG
G230
G30
LPG
G31
(pressures in mbar) - Tab. 1
10. Change nr. 5 and nr. 6 switch on PCB to ON
position (Fig.5) to force appliance to high
forced combustion and open all hot water taps
(CAUTION: advise users not to use water).
11. Adjust pressure setting to the maximum value
(Tab. 2 below) adjusting screw on PCB
(Fig.7).
MAX
GAS
Continuum 11i (11i-fp)
G20
NG
G230
G30
LPG
G31
(pressures in mbar) - Tab. 2
12. Set nr. 5 and nr. 6 switch on PCB to OFF position (Fig.5) for normal combustion and
close taps.
13. Isolate gas supply and cut off power supply.
14. Remove digital manometer and set pressure point screw with o-ring (Fig. 4).
15. Connect gas and check for gas leakages.
16. Connect operating controller connector (Fig. 2).
17. Set front cover (2 screws) (Fig. 1) and connect power.