Rinnai REU-1110FFU-E Installation And User Manual page 24

Continuous flow water heater
Table of Contents

Advertisement

FLUE REQUIREMENTS
BS5440—1 : 2008
Symbol
Directly below an opening, air brick, opening windows, ect.
A
Above an opening, air brick, opening window, ect.
B
C
Horizontaly to an opening, air brick, opening window, ect.
Below plastic gutters, soil pipes, drain pipes, ect.
D
E
Below eaves
Below balconies or car port roof
F
G
From vertical drain pipe or soil pipe
From and internal or external corner
H
I
Above ground, roof or balcony level
From surface facing the terminal
J
K
From terminal facing terminal
L
From opening in the car port (eg door, window ect) into the dwell-
Vertically from terminal on the same wall
M
Horizontally from terminal on the same wall
N
O
From the wall on which the terminal is mounted
From a vertical structure on the roof
P
Above intersection with the roof
Q
BS5440—1 : 2008
Terminal Position
24
Dimen-
sion
300mm
300mm
300mm
75mm
200mm
200mm
150mm
300mm
300mm
600mm
1200mm
1200mm
1500mm
300mm
0
N/A
300mm

Hide quick links: