Electrical Requirements
Figure 39. Interface power requirements
Line
24 Vac
voltage
Transformer
Table 10. Electric heat voltage ratings
Unit Voltage
208
230
460
575
Table 11.
Electric heat kW limits (min/max)
Motor
3
208 V / 60 Hz / 3 PH
6/13
230 V / 60 Hz / 3 PH
6/13
460 V / 60 Hz / 3 PH
6/13
575 V / 60 Hz / 3 PH
6/13
Min airflow (CFM)
1050
Notes: Units drawing less than 100 amps are available with or without door interlocking disconnect. Units drawing more than 100 amps are not available
with door interlocking disconnect.
Units drawing less than 48 amps are available with or without line fusing. Units drawing greater than 48 amps have line fusing as standard.
Units with electric heat must not be run below the minimum cfm listed above.
Heaters available in the following kW increments: 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38, 41, 44, 47,
50, 53, 56, 59, 63, 67, 71, 75, 79, 83, 87, 91, 95, 100, 110, 115, 120.

Fuse Sizes

The standard ampere ratings for fuses and inverse time
circuit breakers are listed in
inverse time circuit breakers with non-standard ampere
ratings shall be permitted provided the rating does not
exceed the maximum fuse size defined on the unit
nameplate.
Table 12. Standard fuse sizes (amperes)
15
20
25
30
35
80
90
100
110
125
300
350
400
450
500
1200 1600 2000 2500 3000 4000 5000 6000
44
Termination board
Heater Voltage
208
240
480
600
6
8
10
6/26
7/28
8/41
6/26
7/32
8/41
6/24
7/32
8/44
6/26
7/34
8/44
2100
2800
3500
Table
12. The use of fuse and
40
45
50
60
150
175
200
225
250
600
700
800
1000
Useful formulas:
kW = (Airflow x Delta T)/K
Delta T = (kW x K)/Airflow
K = 3145 (English)
K = 824.7 (SI)
Heater input current = (kW x 1000)/(Voltage x 1.73)
MCA = Minimum Circuit Ampacity
MOP = Maximum Overcurrent Protection rating or
Maximum fuse size
12
14
10/50
12/50
14/50
10/53
12/59
14/59
10/53
12/63
14/75
10/53
12/63
14/75
4200
4900
70
17
21
25
17/50
20/47
17/59
20/56
17/95
20/95
17/95
20/95
5950
7350
8750
CLCH-SVX009A-EN
30
20/41
20/50
20/120
20/120
10,500

Hide quick links: