Trouble Shooting Mag Transmitter - Siemens MAG 1100 F Operating Instructions Manual

Electromagnetic flowmeters
Hide thumbs Also See for MAG 1100 F:
Table of Contents

Advertisement

SITRANS F M
9.2
Trouble shooting
MAG transmitter
84
9. Service
Symptom
Output
signals
Empty display
Minimum
No flow signal
Minimum
Undefined
Indicates flow
Undefined
with no flow
in pipe
Unstable
Unstable
flow signal
Measuring error
Undefined
Maximum
Measuring
approx. 50%
Loss of totalizer
OK
data
#####
OK
Signs in display
Error
Cause
code
1. No power supply
2. MAG 5000/6000 defective
1. Current output disabled
2. Digital output disabled
3. Reverse flow direction
F70
Incorrect or no coil current
W31
Measuring pipe empty
F60
Internal error
P42
1. No load on current output
2. MAG 5000/6000 defective
P41
Initializing error
Measuring pipe empty
Empty pipe cut-off is OFF
Electrode connection missing/
electrode cable is insufficiently
screened
1. Pulsating flow
2. Conductivity of medium
too low
3. Electrical noise potential
between medium and
sensor
4. Air bubbles in medium
5. High concentration of par-
ticles or fibres
Incorrect installation
®
P40
No SENSORPROM
unit
®
P44
CT SENSORPROM
unit
F61
Defective SENSORPROM
F62
Wrong type of SENSORPROM
unit
F63
Defective SENSORPROM
F71
Loss of internal data
W30
Flow exceeds 100% of Q
W21
Pulse overflow
Volume/pulse too small
Pulse width too large
Missing one electrode
connection
W20
Initializing error
Totalizer roll over
Remedy
Power supply
Check MAG 5000/6000 for
bended pins on the connector
Replace MAG 5000/6000
Turn on current output
Turn on digital output
Change direction
Check cables/connections
Ensure that the measuring
pipe is full
Replace MAG 5000/6000
Check cables/connections
Replace MAG 5000/6000
Switch off MAG 5000/6000,
wait 5 s and switch on again
Select empty pipe cut-off
Ensure that the measuring
pipe is full
Ensure that electrode cable
is connected and sufficiently
screened
Increase time constant
Use special electrode cable
Ensure sufficient potential
equalization
Ensure medium does not
contain air bubbles
Increase time constant
Check installation
Install SENSORPROM
Replace SENSORPROM
or reset SENSORPROM
with MAG CT transmitter
®
unit
Replace SENSORPROM
®
Replace SENSORPROM
®
unit
Replace SENSORPROM
Replace MAG 5000/6000
Check Q
(Basic Settings)
max.
max.
Change volume/pulse
Change pulse width
Check cables
Reset totalizer manually
Reset totalizer or increase
totalizer unit
®
unit
®
unit
®
unit
®
unit
®
unit
®
unit

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mag 1100Mag 3100Mag 3100 pMag 5000Mag 6000Mag 5100 w

Table of Contents