5. Black Limit Adjustment (PD-139 board)
(DCR-TRV530)
Set the dynamic range of the LCD driver to an appropriate level. If
deviated, the LCD screen will become blackish or saturated
(whitish).
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 4 of CN5502 (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A6
Specified Value
A = 8.10 ± 0.08V
Adjusting method:
Order Page Address Data
1
0
01
01
2
2
0E
61
3
2
0F
5B
4
D
A6
5
D
A6
6
2
0E
00
7
2
0F
00
8
0
01
00
9
A
V
Fig. 5-1-20.
Procedure
Set the data.
Set the data.
Set the data.
Change the data and set the PSIG
signal amplitude (A) to the specified
value.
(The data should be "00" to "0F".)
Press PAUSE button.
Set the data.
Set the data.
Set the data.
Check that the specified value of
"RGB AMP Adjustment" is
satisfied. If not, perform "RGB
AMP Adjustment".
6. Contrast Adjustment (PD-138 board)
(DCR-TRV230/TRV330)
Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
2
D
AA
3
D
AA
4
0
01
0 IRE
5-32
VTR stop
No signal
Pin 3 of CN5502 (VG)
External trigger: Pin 4 of CN5502
(PANEL COM)
Oscilloscope
D
AA
A = 3.50 ± 0.07V
Procedure
01
Set the data.
Change the data and set the voltage
(A) between the 100 IRE and 0 IRE
(pedestal) to the specified value.
(The data should be "00" to "7F".)
Press PAUSE button.
00
Set the data.
100 IRE
2H
Fig. 5-1-21.
A