Reader RF350R with ANT 12 and with ISO transponders (MDS D)
Table 4- 44
Transponder
MDS D117
MDS D127
MDS D160
MDS D421
MDS D428
MDS D460
MDS D521
MDS D528
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
Reduction of field data due to metal, range as %: Transponder and RF350R with ANT 12
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 0 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 0 mm
Without metal
1)
On metal; distance 10 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 0 mm
Without metal
On metal; distance 0 mm
Without metal
1)
On metal; distance 10 mm
without metal
on metal; distance 0 mm
flush-mounted in metal;
distance all round 0 mm
without metal
on metal; distance 0 mm
Planning the RF300 system
4.3 Installation guidelines
ANT 12 without metal
100
90
65
100
95
65
100
100
100
90
70
100
95
100
100
??
??
??
??
??
ANT 12 mounted in met-
al
(0 mm all-round)
85
85
65
85
85
65
80
80
80
75
60
75
75
80
80
??
??
??
??
??
79