Siemens SIMATIC Ident System Manual page 70

Identification rfid systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Planning the RF300 system
4.3 Installation guidelines
Transponder
RF370T
RF380T
Mounting the transponder on or in metal is only possible with the appropriate spacer or if there is
1)
adequate clearance to the metal.
With ISO transponders (MDS D)
Table 4- 36
Transponder
MDS D100
MDS D124
MDS D126
MDS D139
MDS D160
MDS D165
70
Without metal
On metal; distance 0 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
On metal; distance 0 mm
Flush-mounted in metal; dis-
tance all-round 40 mm
Reduction of field data due to metal, range as %: Transponder and RF340R
Without metal
1)
On metal; distance 20 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
1)
On metal; distance 15 mm
Flush-mounted in metal;
distance all round 20 mm
Without metal
1)
On metal; distance 25 mm
Flush-mounted in metal;
distance all round 50 mm
Without metal
1)
On metal; distance 30 mm
Flush-mounted in metal;
distance all round 100 mm
Without metal
1)
On metal; distance 10 mm
Without metal
On metal; distance 25 mm
RF340R reader
Without metal
On metal
100
95
95
90
70
65
100
95
100
95
80
75
RF340R reader
Without metal
On metal
100
90
70
65
60
45
100
95
85
85
80
80
100
90
80
80
75
75
100
95
100
90
100
90
100
95
85
85
100
95
90
80
System Manual, 07/2016, C79000-G8976-C345-0x
Flush-mounted
in metal
(20 mm all-
round)
80
75
65
75
70
60
Flush-mounted
in metal
(20 mm all-
round)
75
60
45
80
75
45
85
70
65
80
75
75
80
75
85
75
SIMATIC RF300

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf300

Table of Contents