5.5.2.6

Metal-free area

The RF350R reader does not have an internal antenna. Operation is not affected by
mounting on metal or flush-mounting in metal. For information about the metal-free area
required by the external antennas, refer to the corresponding section of the chapter
"Antennas (Page 193)".
5.5.2.7

Technical specifications

Table 5- 24
Product type designation
Radio frequencies
Operating frequency, rated value
Electrical data
Maximum range
Maximum data transmission speed
reader ↔ transponder
Transmission speed
Read/write distances of the reader
MTBF (Mean Time Between Failures)
Interfaces
Electrical connector design
Antenna connector design
Standard for interfaces for communication
Antenna
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
Technical specifications of the RF350R reader
ANT 1
ANT 3
ANT 12
ANT 18
ANT 30
Read
Write
5.5 SIMATIC RF340R/RF350R - second generation
6GT2801-4BA10
SIMATIC RF350R
13.56 MHz
140 mm
50 mm
16 mm
35 mm
55 mm
RF300
ISO
transponder
transponder
(MDS D)
≤ 8000
bytes/s
≤ 8000
bytes/s
19.2, 57.6, 115.2 kBd
See section "Field data for transponders, readers
and antennas (Page 48)."
260 years
M12, 8-pin
M8, 4-pin
RS-422 (3964R protocol)
External, antennas ANT 1, ANT 3, ANT 12, ANT
18 or ANT 30
Readers
ISO tran-
sponder
(MDS E)
≤ 3300
≤ 3400
bytes/s
bytes/s
≤ 1700
≤ 800
bytes/s
bytes/s