5.7.6
Metal-free area
The RF380R can be flush-mounted in metal. Please allow for a possible reduction in the field
data values.
Figure 5-27
To avoid any impact on the field data, the distance a should be ≥ 20 mm.
5.7.7
Minimum distance between several RF380R Scanmode readers
RF380R side by side
D ≥ 400 mm (with 2 readers)
D ≥ 500 mm (with more than 2 readers)
Figure 5-28
SIMATIC RF300
System Manual, 07/2016, C79000-G8976-C345-0x
Metal-free area for RF380R
Minimum distance between RF380R readers