Memory Areas
Word(s)
Bit(s)
00 to 04
267
05
06 to 12
13
14 and 15
268
00 to 15
00 to 07
269
08 to 10
11 to 13
14
15
00
270
01
02
03
04 to 10
11
12
13
14
15
00 to 07
271
08 to 15
272
00 to 10
11
12
13
14
15
456
Reserved by system (not accessible by user)
Host Link Level 0 Send Ready Flag
Reserved by system (not accessible by user)
Host Link Level 1 Send Ready Flag
Reserved by system (not accessible by user)
Reserved by system (not accessible by user)
Memory Cassette Contents
Memory Cassette Capacity
0: 0 KW (no cassette); 3: 16 KW
Reserved by system (not accessible by user)
EEPROM Memory Cassette Protected or EPROM Memory Cassette Mounted Flag
Memory Cassette Flag
Save UM to Cassette Bit
Load UM from Cassette Bit
Compare UM to Cassette Bit
Comparison Results
0: Contents identical; 1: Contents differ or comparison not possible
Reserved by system (not accessible by user)
Transfer Error Flag:
Transferring SYSMAC NET
data link table on UM during
active data link.
Transfer Error Flag: Not
PROGRAM mode
Transfer Error Flag: Read Only
Transfer Error Flag: Insufficient
Capacity or No UM
Transfer Error Flag: Board
Checksum Error
Ladder program size stored in Memory Cassette
Ladder-only File: 04: 4 KW; 08: 8 KW; 12: 12 KW; ... (64: 64 KW)
00: No ladder program or no file
Data updated at data transfer from CPU at startup. The file must begin in segment 0.
Ladder program size and type in CPU (Specifications are the same as for bits 00 to 07.)
Data updated when indexes generated. Default value (after clearing memory) is 16.
Reserved by system (not accessible by user)
Memory Error Flag: PC Setup Checksum Error
Memory Error Flag: Ladder Checksum Error
Memory Error Flag: Instruction Change Vector Area Checksum Error
Memory Error Flag: Memory Cassette Online Disconnection
Memory Error Flag: Autoboot Error
Function
00: Nothing; 01: UM; 02: IOM (03: HIS)
Data transferred to Memory Cassette when Bit is turned
ON in PROGRAM mode. Bit will automatically turn OFF.
ON i PROGRAM
d
An error will be produced if turned ON in any other
An error will be produced if turned ON in any other
mode.
Data will not be transferred from UM to the Memory
Cassette if an error occurs (except for Board Checksum
Error). Detailed information on checksum errors
occurring in the Memory Cassette will not be output to
g
SR 272 because the information is not needed. Repeat
S
the transmission if SR 27015 is ON.