Honeywell GasAlert Max XT II User Manual page 46

Hazardous gas detection system
Table of Contents

Advertisement

Alarm
Multi-Gas Alarm
• Alternating low and high alarm siren and flash
• L and target gas bar flash
• Vibrator alarm activates
Over Limit (OL) Alarm
• Fast siren and alternating flash
• L and target gas bar flash
• Vibrator alarm activates
If enabled, during an alarm condition the Latched Alarms option causes the low and high gas alarms (audible, visual, and vibrator)
to persist until the alarm is acknowledged (by pressing C) and the gas concentration is below the low alarm setpoint. The LCD displays the
peak concentration until the alarm condition no longer exists. Enable/disable Latching Alarms in Fleet Manager II. Local regulations may
require Latching Alarms be enabled.
Table 7. Alarms
Screen
Sensor Alarm
• ERR displays
Low Battery Alarm
• Sequence of 10 rapid sirens and alternating
flashes with 7 seconds of silence in between
(continues for 10 minutes)
and L flashes
• LOW BATTERY displays and the vibrator alarm
activates
• After 10 minutes, a sequence of 10 rapid sirens
and alternating flashes with 1 second of silence
in between (reactivates seven times)
• TURNING OFF displays before the detector
deactivates
Note
Alarm
GasAlertMaxXT II
Alarms
Screen
34

Hide quick links: