Location Logging; Force Block Test; Datalog Interval - Honeywell GasAlert Max XT II User Manual

Hazardous gas detection system
Table of Contents

Advertisement

GasAlertMaxXT II
User Manual

Location Logging

The Location Logging logs where the detector is being used such as a
gas plant, well site, vehicle, etc.
If enabled, the detector prompts for a three digit value (1-999) to be
entered during the startup tests.
To enter a number from 1-999, continue pressing C until the desired
number displays. To scroll rapidly, press C and hold.
The location entries are recorded in the datalogs.
The detector is shipped with the Location Logging option disabled.
26

Force Block Test

The force block test verifies the pump is operating correctly by compar-
ing the pump flow against the blocked flow. If the Force Block option is
enabled, you will be prompted to manually block the pump inlet
• during the startup tests when the detector is activated, and
• when a pump alarm is acknowledged.
The diffusion cover must be attached for the pump to
operate.
If the block pump test is unsuccessful, the detector deactivates.
For more information about the block test that is performed during
startup, refer to
Pump Test on
The detector is shipped with the Force Block Test option disabled.

Datalog Interval

The Datalog Interval (seconds) field defines how often the detector
records a datalog sample (every 1-120 seconds). Enter the desired
value.
a Caution
Startup.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents