8.5 Climatic ambient conditions
The device meets the requirements according to IEC 60721-3-3 Class 3K3 with the following
amendments and limitations:
Type of condition
Temperature,
Mounting in horizontal format
Temperature,
Mounting in vertical format
Atmospheric pressure
operation elevation
Relative humidity
Pollutant concentration
TP1900 Comfort and TP2200 Comfort: 0 ... 45 °C
1
No pressure difference is allowed inside and outside the enclosure / control cabinet
2
Read the Notes on use (Page 30).
Also observe the climate diagram in the following section and the specifications for the
extended inclination and ambient temperature range; see section
"Selecting a mounting position (Page 34)".
Note
The system components connected to the HMI device, the power supply for example, must
also be suited to the respective operating conditions.
8.5.4

Climate diagram

The diagram below shows the extended range for temperature and humidity during
continuous operation based on IEC 60721-3-3 Class 3K3.
The information applies to a device installed in landscape without inclination.
Red: Extended temperature range of 7-15" devices; see section
"Selecting a mounting position (Page 34)".
192
Mounting position
Vertical
Inclined, maximum inclination 35°
Vertical
Inclined, maximum inclination 35°
,
1140 ... 795 hPa, corresponds to an elevation of -1000 to 2000 m
2
From 10 to 90%, without condensation
SO2: < 0.5 ppm; relative humidity < 60%, no condensation
H
S: < 0.1 ppm; relative humidity < 60%, no condensation
2
Permitted range
0 ... 50 °C
0 ... 40 °C
0 ... 40 °C
0 ... 35 °C
Operating Instructions, 07/2017, A5E36770603-AB