Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Fluke Manuals
Multimeter
8010A
Instruction manual
Probe Accessories Specifications; H Touch-Hold Probe 600-2; Ac Current Probe 600-2; Ac Current - Fluke 8010A Instruction Manual
Hide thumbs
Also See for 8010A
:
Instruction manual
(73 pages)
,
User manual
(49 pages)
,
Operating instructions manual
(9 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
Table Of Contents
74
page
of
74
Go
/
74
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
ACCESSORIES
PROBE ACCESSORIES
Table
600-1.
Probe
Accessories
Specifications
80T-H
TOUCH-HOLD PROBE
Voltage Ratings
TIP
TO
COMMON
.
1000V dc
or
peak
ac
maximum
COMMON
TO
GROUND
.
60V dc
or
42V peak
ac
maximum
Input
Capacitance
.
150
pF
maximum
Lead
Resistance
.
0.50
maximum
80T-150C
AND
80T-150F
TEMPERATURE PROBES
Range
(«C/°F)
.
50®
C
to
-FI
50° C/-58°
F
to
302°
F
Accuracy
.
±1°C
(1.8° F)
from
0°Cto
100°C, decreasing
linearly
to
±3°
C
(5.4°
F)
at-50°C and
+150°C
Sensitivity
1mVdc/°Cor°F
Resolution
.
0.1
°C
or
0.1°
F
recommended
maximum
Voltage Standoff
:
.
350V
dc
or
peak
ac
Power
.
Internal
disposable
battery;
1.000
hours
of
continuous use
801-400
AC CURRENT
PROBE
Range
,
1A
to
400A
Accuracy
.
±{3%
+
0.4A)
48
Hz
to
440
Hz
±(4%
-F
0.4A)
440
Hz
to
1000
Hz
Output
.
1
milliamp per
ampere
of input current
(1
mA/A)
Working
Voltage
.
660V
ac
rms
maximum
Maximum
Conductor
Size
.
1
ea.
30
mm
(1.18")
or
2
ea.
25
mm
(0.98")
Shunt
(load)
Resistance
.
Less than 12
ohms
at
multimeter
input
to
maintairi
specified
accuracy
Typical
Bandwidth
.
-10%
at
40
Hz and
5
kHz
(1A,
400
Hz
reference,
excludes multimeter
response)
Usable Current
Range
.
0.1A
to
600A, 5
seconds
maximum
above 400A
Safety
.
Protection
Class
ii
as
defined
in
lEC 348 and
ANSI
C39.5
801-600
AC CURRENT PROBE
Range
.
1
to
600A
ac
Accuracy
.
±3%
Frequency Response
.
30
Hz
to
1
kHz, 10
kHz
typical
Division Ratio
.
1000:1
Working
Voltage
.
750V rms
maximum
Insulation Dielectric
Withstand Voltage
.
5
kV
Maximum
Conductor
Size
.
2-inch
diameter
80J-10
CURRENT SHUNT
Shunt
.
10
amps
at
100
mV
Accuracy
(18X
to 28'»C)
DC TO
10
KHZ
.
±0.25%
10
KHZ-100
KHZ
.
Rising
to
1
dB
at
100
kHz
typical
Temperature
Coefficient
.
0.005%/°
C
inductance
.
8.3
nH
in
series
w/O.OIQ
shunt
Overload
.
Up
to
one
minute
at
20A
with a
1/4
duty cycle
for
recovery
after
currents
between 10A and 20A
Connects
to
.
3/4 inch
center
banana
jacks
Connectors
.
5-way
binding posts
(red
and
black)
600-6
Table of
Contents
Previous
Page
Next
Page
1
...
56
57
58
59
60
61
62
63
Show Quick Links
Quick Links:
Specifications
Schematic Diagrams
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Related Manuals for Fluke 8010A
Multimeter Fluke 8010A Instruction Manual
(73 pages)
Multimeter Fluke 8010A User Manual
(49 pages)
Multimeter Fluke 8012A Instruction Manual
(13 pages)
Multimeter Fluke 8010A Operating Instructions Manual
(9 pages)
Multimeter Fluke 80 Series III User Manual
Fluke power supply 80 series iii users manual (58 pages)
Multimeter Fluke 80 series III Getting Started
(17 pages)
Multimeter Fluke 80 SERIES III Service Information
(34 pages)
Multimeter Fluke 80 Series V User Manual
(60 pages)
Multimeter Fluke 80 Series V Getting Started Manual
80 series v multimeters (28 pages)
Multimeter Fluke 87V/IMSK User Manual
(60 pages)
Multimeter Fluke 8060A Instruction Manual
True-rms multimeter (140 pages)
Multimeter Fluke 8020A Instruction Manual
(80 pages)
Multimeter Fluke 8020A Instruction Manual
(49 pages)
Multimeter Fluke 8030A Instruction Manual
(47 pages)
Multimeter Fluke 8050A Instruction Manual
(106 pages)
Multimeter Fluke 8050? Instruction Manual
Digital multimeter (101 pages)
Related Content for Fluke 8010A
115C General Specifications
Fluke 115C
87V Specifications
Fluke 87V
116 Specifications
Fluke 116
233 General Specifications
Fluke 233
175 Specifications
Fluke 175
110 Specifications
Fluke 110
1587 MDT Accessories
Fluke 1587 MDT
II Series Specifications
Fluke II Series
8050A H Touch-Hold Probe
Fluke 8050A
8505A Specifications
Fluke 8505A
8010A Specifications
Fluke 8010A
a3002 FC Specifications
Fluke a3002 FC
87 III Series Parts And Accessories
Fluke 87 III Series
IB117L Specifications
Fluke IB117L
87V/IMSK Specifications
Fluke 87V/IMSK
8050A Probe Accessories Specifications
Fluke 8050A
This manual is also suitable for:
8012a
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL